Wilkins NR3 Water Pressure Reducing
Valve

Specification Sheet |
Wilkins
NR3 Water Pressure Reducing Valve with Integral By-pass check Valve and Strainer
Designed for installation on potable water lines to reduce high inlet pressure to a lower outlet pressure. The integral strainer makes this device most suitable for residential and commercial
water systems that require frequent cleaning of sediment and debris. The direct acting integral by-pass design prevents buildup of excessive system pressure caused by thermal expansion.
The balance piston design enables the regulator to react in a smooth and responsive manner to changes in system flow demand, while at the same time, providing protection from inlet pressure changes.
|
|
|
|
|
Specifications
|
TYPICAL INSTALLATION
Local codes shall govern installation requirements. Unless otherwise specified, the assembly shall be mounted in accordance
with the latest edition of the Uniform Plumbing Code. The Model NR3XL may be installed in any position. If installed in a pit, vault, or inside application, specify the
"SC" sealed cage option. The assembly shall be installed with sufficient
side clearance for testing and maintenance. Multiple installations are recommended for wide demand variations or where the desired pressure reduction is more than 4 to 1 (ie: 200 psi inlet reduced to 50 psi outlet). CAUTION: Anytime a reducing valve is adjusted, a pressure gauge must be used downstream to verify correct pressure setting. Do not bottom adjustment bolt on bell housing.

SPECIFICATIONS
The Water Pressure Reducing Valve shall be ANSI 3rd party certified to comply with states' lead plumbing law 0.25% maximum weighted average lead content requirement, and ASSE Listed 1003, available with single union, double union and less union end connections. The main body shall be low lead cast bronze (ASTM B 584) alloy. The bell shall be composite plastic. The cartridge shall be NSF Listed acetal and incorporate an integral seat. The seat disc elastomer shall be NSF Listed EPDM. The assembly shall be accessible for maintenance without removing the device from the line. The Water Pressure Reducing Valve shall be a WILKINS Model NR3XL.
|
|
Return to
Wilkins Products |
|
Air
Fresheners | Microburst
3000 | Microburst
9000 | Automatic
Flushers
Automatic Faucets
| Soap
Dispensers | Xlerator
Hand Dryers | Shower
Heads
WaterFree Urinals
| Sloan Flush Valves
| Automatic Fixture
Cleaners
Sloan Valve Products | TCell
Air Fresheners | Technical
Concepts Products
Bathroom Paper Products | T&S
Brass | Andersen
Floor Mats
HydroVantage
Flush Valve | Browse
Products by Manufacturer
Phone Toll Free 1-800-440-5556
|
Fax: 1-866-243-5689
or email us at customer_service@airdelights.com
Privacy Policy
|
Site Map | Find
us on Facebook
Copyright © 1991 - 2012 Air Delights, Inc., All rights reserved
|